Basic maintenance: Eiki SL (in progress)

From Filmwerkplaats MediaWiki
Jump to navigation Jump to search

Safety rules

Never put your fingers close to the shutter when the projector is on.

Unplug the projector before you touch the lamp holder.

Avoid touching the side of the capacitor, which can retain electricity for a long time.

Step-by-step basic maintenance: Eiki SL

We checked an Eiki SL in the workshop.

1. Take down the cover.

2. Make sure the inner lamp cover is in a good position.

3. Check the rollers and make sure they are clean and smooth.

4. Check the lamp and lamp holder. In case of oxidation, clean them with sandpaper. If there is still no light, check the fuses.

5. Check the focus knob and make sure it is smooth (no. 16 in Fig. #61. For more info, see Eiki NT service manual p.44).

Projector focus knob p44.png

6. Clean the aperture plate and film gate plate (no. 26 and no. 27 in Fig. #58. For more info, see Eiki NT service manual p.43).

Projector film gate p43.png

7. Check the sound exciter lamp. If the sound lamp is on but there’s no sound, it means the fuse might be broken.

8. Run the test film. If the projector doesn’t take up the film well, clean the claw mechanism and realign it (For details see Fig. #33 in Eiki NT service manual p.28).

 8.1 Loosen screw (A) to be able to adjust screw (B) and screw (C).
 8.2 screw (B) is for adjusting the "claw protrusion," which means the "horizontal" position of the claw.
 8.3 screw (C) is for adjusting the vertical position of the claw.
Claw protrusion p28.png
Claw mechanism.png

9. Take off the front-bottom cover for cleaning the film path.