ECN process: Difference between revisions

From Filmwerkplaats MediaWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 1: Line 1:
ECP PROCESSING
ECN PROCESSING NEW CAMERA FILM - NO REMJET


{| class="wikitable"
{| class="wikitable"
Line 8: Line 8:
|-
|-
!PRE WASH ( with warm water )
!PRE WASH ( with warm water )
!± 38
!41-42
!2 - 5 min
!5 min
|-
|-
!ECP-1( Developer)
!ECN-1( Developer)
!36.7 ±  0.1
!41.1 ±  0.1
!3 min
!3 min
|-
|-
!ECP-2 (Stop)
!ECN-2 (Stop)
!'''27 -  or more'''
!'''27 -  or more'''
!1 min
!1 min
Line 23: Line 23:
!30 sec each
!30 sec each
|-
|-
!ECP/N3 (Bleach)
!ECN/P-3 (Bleach)
!'''27 -  or more'''
!'''27 -  or more'''
!'''1 -3 min'''
!'''1 -3 min'''
Line 31: Line 31:
!30 sec each
!30 sec each
|-
|-
!ECP/N-4 (FIX)  
!ECN/P-4 (FIX)  
!'''27 -  or more'''
!'''27 -  or more'''
!'''2 - 3 min'''
!'''2 - 3 min'''
Line 40: Line 40:
|-
|-
!Photoflo
!Photoflo
!27 ± 1
!cold / room temp.
!'''30 sec'''
!'''1 min'''
|}
|}

Latest revision as of 21:50, 7 October 2025

ECN PROCESSING NEW CAMERA FILM - NO REMJET

Temperature °C Time
PRE WASH ( with warm water ) 41-42 5 min
ECN-1( Developer) 41.1 ± 0.1 3 min
ECN-2 (Stop) 27 - or more 1 min
wash 2x fresh water 27 - or more 30 sec each
ECN/P-3 (Bleach) 27 - or more 1 -3 min
wash 3x fresh water 27 - or more 30 sec each
ECN/P-4 (FIX) 27 - or more 2 - 3 min
Wash (under running water) cold / room temp. 2 min or more
Photoflo cold / room temp. 1 min